1A1-A18 頸部血流計測ロボットシステムの開発
宇田 寿人貞光 雄志有野 千昭原田 烈光菅原 基晃仁木 清美高西 淳夫
著者情報
会議録・要旨集 フリー

詳細
抄録
We developed a robot system for the conventional measurement of the carotid blood flow using an ultrasonic diagnostic equipment, aiming at reduction of the patient and doctor burden. The authors developed a probe manipulator consisted of 6-DOF linear parallel link mechanism and a 6-DOF passive positioning arm for adjusting the probe manipulator. This positioning arm consists serial link and parallel link. This manipulator operation adopted two method, direct input by virtual compliance control and remote control by external input device. Furthermore, we constructed an image processing algorithm to detect tunica intima and a probe control algorithm for searching the best section automatically in a long axis measurement.