The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
Online ISSN : 2424-3124
2009
Session ID : 2A1-A13
Conference information
2A1-A13 Non-contact transportation Technique for board by Ultrasonic Oscillation (2nd report) : Characteristics of Non-contact Handling Device
Hiromi ISOBE
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
In recent years, various boards such as glass substrate and semiconductor wafers have become larger. Therefore, fracture of substrates under conventional contact transportation is unavoidable. In order to solve these problems, a new non-contact transportation technology is proposed. The board is levitated by aerostatic force and held by the holding unit constructed by oscillating plate actuated by bolted Langevin transducer. In this paper, noncontact holding force was measured. The holding force is varied with overlap area between substrate and oscillating plate. As the holding units hold the substrate, the units are traveled along the transportation road. As a result, the substrate moves without any contact.
Content from these authors
© 2009 The Japan Society of Mechanical Engineers
Previous article Next article
feedback