The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
Online ISSN : 2424-3124
2013
Session ID : 1A1-D12
Conference information
1A1-D12 Measurement of Intracellular Viscosity using Nanomachine Powered by Magnetic Field(Bio Manipulation)
Koki MIYAZAKITakashi KATAYAMAYoshitake AKIYAMAKeisuke MORISHIMA
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
In this report, a method to measure cytoplasmic viscosity using a nano machine was proposed. We fabricated magnetically driven nano machine by spattering nickel on the suface of carbon nano coil. The nano machine was introduced into the epidermal cell of commelina communis using microinjection. We calculated cytoplasmic viscosity by measuring the magnetic flux density of the nano machine when losing steps. As the magnetic field gets weaker, the nano machine eventually loses its steps. The relationship between the viscosity and the magnetic flux density applied to the nano machine when losing steps is given by η=kB^2, where k is the coefficient for each nano machine. Based on this theory we measured the cytoplasmic viscosity of commelina communis and obtained the viscosity of 1.1±0.2 mPa・s.
Content from these authors
© 2013 The Japan Society of Mechanical Engineers
Previous article Next article
feedback
Top