抄録
This paper presents that generating mechanism of shaft voltage leading to electric erosion. The voltage generator of shaft voltage is expected to be cause by voltage in winding wire. We construct circuit of interior motor and do predictive simulation of the circuit. We measure the neutral voltage and draw a comparison between predictive value and measured value. As a result, there are obvious connections between predictive value and measured value.