階段昇段可能な大腿義足用機械式膝継手における膝折れ防止機構
杉本 達也井上 恒和田 隆広パリプンノチャイ アナンヤー田中 丈博
著者情報
会議録・要旨集 フリー

詳細
抄録

We previously developed a passive knee joint mechanism that enabled level walk and stair ascent with a transfemoral prosthesis, and stability of transfemoral prosthesis has been established in level walk mechanism. However, stability of transfemoral prosthesis has not been established in stair ascent. Unintended knee flexion should be avoided not to fall during both level walking and stair ascending. Therefore, in the present study, we developed a passive knee joint mechanism that prevents knee flexion during stair ascending. In the assessment experiment, the flexion lock function appropriately worked as designed, and the original functions that enable stair ascent were preserved.