The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
Online ISSN : 2424-3124
2018
Session ID : 2A1-D08
Conference information

Development of a wire winding device for grippers of the double spiral mobile robot and grip force measurement
*Kazuki TOUDANaohiko HANAJIMAYoshinori FUJIHIRAMasato MIZUKAMI
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract

This paper addresses development of grippers of the double spiral mobile robot and discussion of its performance by measuring grip force. The double spiral mobile robot has been proposed for providing mobility for the wetland survey. It consists of two pairs of spirals and a four-legged robot. The robot needs to walk on the spirals avoiding tumble. Therefore, the grippers on the tip of the leg have to grasp the spirals tightly. In this research, we developed a prototype of the wire winding mechanism for grip motion and evaluated the wire tension and the grip force. The developed prototype realized the grip force of 183N using 12-volt power window lift motor at the current of 4A. This result implies the positive outlook to develop the gripper generating the required grip force of 758N by improving the efficiency of the transmission mechanism and applying more electrical current.

Content from these authors
© 2018 The Japan Society of Mechanical Engineers
Previous article Next article
feedback
Top