Bionic-EyE:
緑内障模擬手術における強膜切開感の定量的評価
宮原 啓輔小俣 誠二山中 俊郎原田 香奈子光石 衛杉本 宏一郎上田 高志戸塚 清人白矢 智靖荒木 章之高尾 宗之相原 一森田 康之新井 史人
著者情報
会議録・要旨集 認証あり

詳細
抄録

Although an education of surgery is closely related to thinking and procedure, it mainly relies on the oral and video materials of skilled doctors. For this reason, the situation in a surgical technique education is difficult continues worldwide, and many educational programs that provide practical training using many patient models have been developed. In this study, as the first step to clarify the causal relationship between the characteristics of the artificial eyeball and the sensory evaluation of the doctor, the incision reaction force when the artificial sclera with different fiber diameters was incised with a knife was measured, and the incision force was measured. As the results, we were able to measure the reaction force when incising an artificial sclera with a knife, and to determine the relationship of fiber diameter.

著者関連情報
© 2023 一般社団法人 日本機械学会