スターリングサイクルシンポジウム講演論文集
Online ISSN : 2424-2926
セッションID: D13
会議情報
D13 熱音響発振器の基本特性(熱音響エンジン)
周 淑亮鰭崎 有松原 洋一杉田 寛之遠山 伸一
著者情報
会議録・要旨集 フリー

詳細
抄録
Compared with traveling wave thermoacoustic prime mover, standing wave thermoacoustic prime mover has the merit of stability as there is no closed loop in the system. The heat->work conversion efficiency of standing wave type engine is lower than that of traveling wave type theoretically. A standing wave thermoacoustic prime mover has been built to measure its efficiency accurately. Numerical calculations were carried out and the results coincided with experimental results well. Calculations also show that there exists an optimum heat transfer area of stack to get the best efficiency, and also it is true to heat exchangers to improve the efficiency and increase the output power.
著者関連情報
© 2001 一般社団法人 日本機械学会