熱工学コンファレンス講演論文集
Online ISSN : 2424-290X
セッションID: G222
会議情報
G222 マイクロチューブ内の流れと出口における不足膨張との関係(一般講演(9))
松下 晋一洪 定杓浅古 豊上野 一郎
著者情報
会議録・要旨集 フリー

詳細
抄録
Experimental investigations on nitrogen gas flow characteristics were conducted for a micro-tube. The micro-tube was fabricated in a stainless steel block by electrical discharge machining (EDM). The micro-tube was designed with a main flow tube and five pressure ports, which were led to the pressure transducers. The average diameter and the length of the main tube were of 373 μm and of 40 mm, respectively. The outlet of the tube faced to the atmosphere. The pressure of turbulent gas flow through a micro-tube falls steeply and Mach number increases near the outlet with increasing the inlet pressure due to flow acceleration. It is found that there exists a threshold of Mach number at which the local values of friction factor for the turbulent flow regime abruptly increase. In additional experiments, the flow at the micro-tube outlet was visualized by using a Schlieren method.
著者関連情報
© 2011 一般社団法人 日本機械学会