熱工学コンファレンス講演論文集
Online ISSN : 2424-290X
セッションID: A113
会議情報
A113 微小重力場における電線被覆の過電流連続通電着火現象(OS-2:微小重力環境下における燃焼および熱工学的問題)
藤田 修重田 尚樹
著者情報
会議録・要旨集 フリー

詳細
抄録
Ignition tests of overloaded electric wire were carried out in microgravity provided by airplane parabolic flight. Polyethylene insulated NiCr core wire (inner core diameter 0.5 and outer diameter 0.8 mm) was used as a test sample. The results showed that the ignition limit in terms of supplied electric power dramatically decreased with increase in microgravity time. It was suggested that the total electric energy supplied to the wire gave the primary criteria for ignition, which was consistent with experimental findings. Further, the importance of conductive heat loss to the surroundings was pointed out for very low electric current condition according to the simple one-dimensional numerical calculation.
著者関連情報
© 2013 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top