熱工学コンファレンス講演論文集
Online ISSN : 2424-290X
セッションID: E211
会議情報
E211 密閉型モータのファン冷却方式に関する研究(一般講演(8))
小山 泰平伊藤 暁三須 大輔
著者情報
会議録・要旨集 フリー

詳細
抄録
Totally enclosed motor for traction motors of the train and industrial motors can prevent intruding dust and extend the period of disassembly and cleaning. It is difficult to radiate the heat which generate inside the motor during operation. For further cooling performance improvement, the cooling structure by which inner air agitation and the outside ventilation are possible by using one fan was considered. Moreover, cooling performance was improved by the structure which cooling wind was inhaled in both sides of the motor and was exhausted at an iron core center. This paper describes the result evaluated by CFD about the coil temperature of the motor.
著者関連情報
© 2015 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top