熱工学コンファレンス講演論文集
Online ISSN : 2424-290X
セッションID: 0185
会議情報

狭帯域波長のスペクトル強度を用いた感温液晶の新しい温度分布計測法
シャインプルーフ配置による測定法の改善
*小久井 大将鳥山 孝司多田 茂一宮 浩市舩谷 俊平
著者情報
会議録・要旨集 フリー

詳細
抄録

This paper described the development of measurement method of temperature distribution utilizing thermo-chromic liquid crystal, TLC. In the proposed method, temperature was determined using the ratio of scattered light intensities at narrow band blue wavelengths on TLC. Images of light intensity were captured by two monochrome cameras with band-path filters, and these cameras were set to Scheimpflug configurations. The result shows that the temperature for the maximum value of scattered light intensity was differed by the effect of the elevation angle of the camera in comparison for the result of the previous method. In the proposed method, the widest measurable temperature range was 14-44°C using the combination of 436nm/405nm. The uncertainty of the proposed method was improved than previous method.