主催: 一般社団法人 日本機械学会
会議名: 熱工学コンファレンス2021
開催日: 2021/10/09 - 2021/10/10
As a technology of exhaust gas heat recovery, the thermoelectric generator using the loop thermosiphon (LT-TEG) has been developed. The loop thermosiphon can transport exhaust gas heat effectively to the thermoelectric modules. This study has considered installing two LT-TEGs along exhaust gas flow. It is concerned that decrease in the heat input on downstream side causes deviation in the electric output between the two LT-TEGs. To maximize the electric output of both the LT-TEGs, it is necessary to suppress the deviation. To do this, the refrigerant channels of the two LT-TEGs have been connected so that they can share the refrigerant of uniform pressure. Numerical modeling of the joint system and its experimental verification have been performed.