Proceedings of the 1992 Annual Meeting of JSME/MMD
Online ISSN : 2433-1287
2000
Conference information
High precision measurements of inner structures with X-ray image subtraction and CT methods
Yasushi IKEDAYasutoshi MIZUTAKatsuhiro ONDA
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Pages 255-256

Details
Abstract
Both X-ray image subtraction and CT are very useful for imaging inner structures of materials and components, and also for determination quantitatively the dimensions of those structures with fairly higher accuracy. In this paper we report the examples of sizing the diameters of pores in Si3N4 ceramics from the obtained images by both X-ray methods and compare them for discussion of the precision of those data. With the obtained data, both methods are confirmed to be very accurate to determine the sizes of inner structures.
Content from these authors
© 2000 The Japan Society of Mechanical Engineers