Abstract
In order to obtain information about relationships between fatigue strength of a SUS316NG austenitic stainless steel and hardening behavior due to dynamic strain aging during fatigue tests, rotating bending fatigue tests were carried out at 300°C for notched specimens for stress concentration factors being less than 2.0 and for burnished hourglass type specimens. As for the notched specimens, fatigue fracture occurred before the specimens hardened enough during fatigue tests and the fatigue strengths did not reach the expected values from fatigue strengths of notched specimens for stress concentration factor being greater than 2.0. As for the burnished specimens, the specimen surfaces hardened enough previously to fatigue test but the fatigue strength also did not reach the expected value. Internal fracture occurred for burnished specimens and fish-eye patterns were observed on the fracture surfaces.