臨床
試作磁性アタッチメントの臨床応用について
―上顎骨膜下インプラント撤去後,義歯の維持装置として磁性アタッチメントを応用した1症例―
五十嵐 俊男奥森 直人北村 隆今西 泰彦中島 三晴杉藤 庄平岸 民祐村上 広樹倉本 弘樹簗瀬 武史入江 靖雄長谷川 晃嗣
著者情報
ジャーナル フリー

1998 年 11 巻 1 号 p. 58-64

詳細
抄録
Magnetic attachment retainers, which used SUS 430 stainless steel produced by the machining method, were applied to implant treatment. In a patient for whom a denture was repeatedly fabricated because of its instability and detachment due to marked bone resorption after removal of maxillary subperiosteal implants, the amount of bone was confirmed by CT radiography after healing of bone,and then Integral® implants (right side; 3.25 mm in thickness, 6.0 mm in length, left side; 4.0 mm in thickness, 5.0 mm in length) were implanted into the bilateral molar areas. Magnetic attachment retainers were fixed to the implant fixture. A denture was fabricated by the routine method, and the magnetic alloy of HICOREX SUPER J® (right side; 3515, left side; 4015) was fixed to the inner surface of the denture with self-curing resin. No problems, including detachment of denture, were observed, and the patient was satisfied during denture application.
著者関連情報
© 1998 公益社団法人日本口腔インプラント学会