インプラント上部構造物の作製に関する研究
―鋳造精度に室内温度が与える影響―
杉藤 庄平中島 三晴鬼澤 徹森 厚二白鳥 徳彦山倉 和典五十嵐 俊男日高 勇一小野 擴仁吉田 貴光伊藤 充雄
著者情報
ジャーナル フリー

1999 年 12 巻 4 号 p. 477-483

詳細
抄録

It is important to obtain exact fitting of the abutment supported restoration cases to maintain the longevity of osseointegration. In order to reveal the influence of laboratory temperature on the properties of the quick heating investment, the calorific values of mold, the setting expansion, heat expansion and casting shrinkage were measured at 16℃,23℃ and 30℃ under 60% humidity.
The results were as follows:
1. With a rise in room temperature, the calorific value increased.
2. WM had higher calorific value than Q1 and Q2.
3. With a rise in room temperature, the setting expansion was increased.
4. With a rise in room temperature, the heat expansion of Q1 and WM were decreased.
5. With a rise in room temperature, the wax pattern was melted inside the mold.
6. With a rise in room temperature, the casting shrinkage was decreased.