プラズマ・核融合学会誌
Print ISSN : 0918-7928
研究論文
Electron Cyclotron Emission Diagnostics in the Large Helical Device
Yoshio NAGAYAMAKazuo KAWAHATAShigeru INAGAKIShin KUBOKazumichi NARIHARANobuyoshi OHYABUthe LHD Group
著者情報
ジャーナル フリー

2003 年 79 巻 6 号 p. 601-607

詳細
抄録

Electron cyclotron emission (ECE) diagnostics have been developed in the Large Helical Device (LHD). The ECE is transmitted from the antenna to the spectrometer for 80 m by means of a corrugated waveguide system, which has a small transmission loss (˜30%) in LHD. Although the field angle changes from −40 to +30 degrees on the sight-line of the ECE antenna, it has been observed that the polarization of ECE, which is determined at the plasma edge in LHD, is identical for all frequencies. Thus, the electron temperature profile can be measured using the second harmonic X-mode of ECE. The ECE measured by the Michelson is calibrated with a hot source in order to reduce noise. The ECE temperature measurement agrees well with the Thomson scattering measurement over a wide range of electron densities. The radiometer is cross-calibrated to the Michelson, and is employed for the study of fast phenomena such as internal transport barrier (ITB) formation. Tangentially emitted ECE, in addition to the normal ECE, is investigated in LHD in order to explore the potential of ECE diagnostics.

著者関連情報
© 2003 by The Japan Society of Plasma Science and Nuclear Fusion Research
前の記事 次の記事
feedback
Top