日本水処理生物学会誌
Online ISSN : 1881-0438
Print ISSN : 0910-6758
ISSN-L : 0910-6758
ピコ植物プランクトンに起因する浄水処理過程、ろ過水への濁度漏出とその対策について
中村 寿子曽根田 研一宮田 雅典武安 一志
著者情報
ジャーナル フリー

1997 年 33 巻 4 号 p. 233-243

詳細
抄録

Cell concentration of micro-phytoplankton and Flagellates were high in raw water of Kunijima purification plant of Osaka waterworks, from July to August, 1996.
Then, turbidity was leaked to filtrate of water purification system, and the majority of turbid were due to picophytoplankton. Leakage was remarkable in the raw water which was taken in from afternoon to evening. 14 thousands cells/mL of picophytoplankton in filtrates show 0.1 degree of turbidity.
The results of coagulation-sedimentation by jar test examination were follows:
(1) Dosage of combined chlorine was effective. (2) Optimum pH of coagulation and floc formation was<7.2 by aluminium sulfate, <7.4 by polyaluminium chloride. (3) Increase of coagulant dose was effective but cells could not be removed over 99% in spite of 120mg/l dose.
The turbidity<0.1 was achieved by measures of chlorination, increase of coagulant dose, and pH modification.

著者関連情報
© 日本水処理生物学会
前の記事
feedback