Journal of Textile Engineering
Online ISSN : 1880-1986
Print ISSN : 1346-8235
ISSN-L : 1346-8235
Original Papers
JIS A 1455を用いたタイルカーペットの帯電性能の検討
平井 郁子横山 裕
著者情報
ジャーナル フリー

2006 年 52 巻 5 号 p. 197-203

詳細
抄録
The following are the results of an examination of the anti-static effects of the various combinations of tile-carpets and free-access floors, taking the influence of relative humidity into consideration, using JIS A 1455: Anti-static effect of floor coverings and installed floors - Methods of measurement and evaluation.
(1) Relative humidity affects electrification performance, which declines when using free-access floors with the electrostatic tester approved by the Architectural floor special performance society.
(2) The electrification performance of a floor declines when using free-access floors with the electrification between panels and bases between panels and bases eliminated beforehand, even if the same tile-carpets are used. As far as the measurement results at present are concerned, no difference occurs in electrification performance depending on the materials of free-access floors.
(3) Some carpets show different evaluations, when measured by the electrostatic tester of the Architectural floor special performance society, even where there is no difference in the evaluations of electrification using the Strolling method. When using the strolling method, some floor coverings which apparently have lower anti-static quality show lower static electrification performance than those which are vested with anti-static quality.
(4) Carpets which are more receptive to static electricity due to their lower surface and volume resistances tend to have higher electrification performance.
著者関連情報
© 2006 一般社団法人 日本繊維機械学会
前の記事 次の記事
feedback
Top