可視化情報学会誌
Online ISSN : 1884-037X
Print ISSN : 0916-4731
ISSN-L : 0916-4731
C202 X線ホログラフィを利用したPTV計測の可能性の検討
植村 知正山本 恭史村田 滋西尾 茂井口 学上杉 健太朗
著者情報
ジャーナル フリー

2005 年 25 巻 Supplement1 号 p. 203-206

詳細
抄録
Some X-ray imaging techniques are examined for a feasibility study for micro-PIV in this study. There are three X-ray imaging method, the absorption contrast method, the refraction contrast method, and the phase contrast method. The first one is a common method but its spatial resolution is rather poor. The 2nd method corresponds to the Schlieren method that utilizes refraction of parallel light. The characteristics of the method, edge enhancement, can be effective in extracting tracer images. The third method is a kind of holography methods, and this method can record fine tracer particles.
Among the three methods, the second and the third method are seemed to be applicable to PIV imaging, and those methods need a parallel X-ray. The Spring8, the synchrotron radiation facility in Harima, is utilized. There are some methods to realize phase contrast image, most of them requires ultra-high precision in optical alignment. In the present study, though a coherent source is indispensable, the simplest and robust holography method, the inline holography, is used to take phase contrast pictures.
著者関連情報
© 社団法人 可視化情報学会
前の記事 次の記事
feedback
Top