放射線等による圧力測定異常とその対策
大石 真也依田 哲彦谷内 友希子小路 正純米原 博人大熊 春夫
著者情報
ジャーナル フリー

2006 年 49 巻 5 号 p. 302-305

詳細
抄録

  In the SPring-8 Storage Ring, the pressure measured by Bayard-Alpert gauge near photon-absorber were not observed aging effects by a beam self-cleaning. As the result of investigations of this phenomenon, three causes of misreading of pressure measurement were found; (1) irradiation of the scattered X-ray to gauge head, (2) a large amount of electronic inflow to gauge head, (3) irradiation of the scattered X-ray to gauge cable. We took measures to the misreading, for example shielding of gauge heads and cables etc, and came to be able to measure pressure within tens of percent errors.