By using contact angle measurements, we have observed. the sealing range of glass-to-metal seals. Sealing is preferable at contact angles between 25° and 70°.
Over-oxidation of metals generally inhibit the wettability of glasses.
Some components of glasses probably decompose at high temperature and react to the oxide of metals.