生体内吸収性ポリ-L-乳酸骨接合ミニプレート・スクリューシステムの有用性
田部 大黒川 英雄山下 真紀木村 勝彦山本 昌代村田 朋之中村 貴司山下 善弘三浦 恵子
著者情報
ジャーナル フリー

1999 年 53 巻 5 号 p. 651-656

詳細
抄録
We assessed the usefulness of newly developed biodegradable Poly-L-Lactide (PLLA) bone mini plate and screw system for internal fixation of the fracture of the mandible. Biodegradable PLLA bone mini plate and screw system was performed on 9 patients (8 males and 1 female) in our department during 1.5 years from January, 1998 to June, 1999. The ages of patients were ranged from 13 years old to 33 years old (mean 22 years). In our series, no postoperative complications were found as a result of using bioabsorbable materials. We believe PLLA bone plate and screw system is safer and more effective and more valuable for the fracture of the mandible.