日本機械学会論文集 A編
Online ISSN : 1884-8338
Print ISSN : 0387-5008
大腿骨遠位端から股関節を伝ぱする衝撃応力波の解析
皿井 孝明井上 貴之藏本 孝一
著者情報
ジャーナル フリー

2009 年 75 巻 760 号 p. 1657-1662

詳細
抄録

Three-dimensional finite element model of femur and pelvis was prepared and the propagation of impulsive stress wave from the distal femur to the hip joint was analyzed by the dynamic finite element method. The finite element model with no articular cartilage was also used and the influence of cartilage on the impulsive stress was discussed. The stress concentration is mainly found around the femoral neck. The absolute value of minimum principal stress increases in the medial side, and the maximum principal stress increases in the lateral side during the propagation of stress wave. In this case, the absolute value of maximum principal stress is larger than that of minimum one. The stress of pelvis is small compared with that of femur, indicating that the impulsive stress is absorbed by traveling through the cartilage. The stress in the femoral neck and the pelvis becomes large in the case of no cartilage model, therefore it can be said that the hip joint with no cartilage has a higher risk of bone fracture.

著者関連情報
© 2009 社団法人日本機械学会
前の記事 次の記事
feedback
Top