日本機械学会論文集 B編
Online ISSN : 1884-8346
Print ISSN : 0387-5016
V形熱線による低流速の測定 : 第2報,変動速度の測定
辻 俊博長野 靖尚江村 哲二
著者情報
ジャーナル フリー

1987 年 53 巻 487 号 p. 880-884

詳細
抄録

A method of turbulence mesurements at low velocities with V-shaped hot-wires is described along with associated probe arrangements. The present method is based on the simultaneous solution of exact nonlinear equations for the effective cooling velocities, thus providing instantaneous values of velocity components. The validity of the technique was tested for the measurement of turbulent velocity components which were artificially produced by shaking the hot-wire probe with an accurately known motion in a steady flow. Instantaneous velocities obtained with the proposed method were in almost perfect agreement with the corresponding imposed values.

著者関連情報
© 社団法人日本機械学会
前の記事 次の記事
feedback
Top