日本機械学会論文集 B編
Online ISSN : 1884-8346
Print ISSN : 0387-5016
ガラス強化法へのミスト冷却の応用
大久保 英敏西尾 茂文
著者情報
ジャーナル フリー

1988 年 54 巻 501 号 p. 1163-1169

詳細
抄録

This paper presents a feasibility study of glass tempering using mist cooling. First, transient tests of mist cooling were conducted to investigate the effects of the thermal properties of cooling surface. To do this, test plates were made of silver, nickel, stainless steel (SUS304), and fused quartz. The experimental conditions of mist flow were as follows : the air velocity was Va=20 m/s, the temperature of the water droplets Tl=21°C, and the volumetric-droplet-flow-rate D=0.0003-0.01m3/m2s. The experimental data show that both the plate temperature corresponding to the minimum heat flux (TM) and the heat transfer coefficients at wall temperatures above TM increase for decreasing thermal conductance of the surface material. Second, tempering tests of soda-lime glass plates of 2.95 and 3.90 mm thicknesses were conducted using mist cooling. The initial temperature of glass plates was about 690°C. The plates were cooled only from one side. Test results indicate that thin and low-cost tempered glass plates can be made by mist cooling without fracture.

著者関連情報
© 社団法人日本機械学会
前の記事 次の記事
feedback
Top