日本機械学会論文集 B編
Online ISSN : 1884-8346
Print ISSN : 0387-5016
固定電極型放電式翼端すきま測定法の研究
渡辺 高幸松木 正勝
著者情報
ジャーナル フリー

1996 年 62 巻 598 号 p. 2290-2295

詳細
抄録

We have devised a new method for tip clearance measurement which does not require an actuator to move the discharge probe. The applications of this method and its characteristics were investigated, and tip clearance measurements were attempted. As a result, it was found that UV irradiation was indispensable for obtaining a constant discharge voltage in the range of 98kPa∼196kPa. The discharge characteristics varied with pressure, but a linear relationship could be obtained. The discharge characteristics varied with the shape of the rotor. Hence, this factor must be checked prior to measurement. The probes produced were not affected by the peripheral velocity of up to 80m/s. Measurement accuracy using a core-type probe was within ±0.05mm, and with a cylinder-type was within ±0.lmm. The cylinder-type probe was able to measure the tip clearance up to a peripheral velocity of 270m/s.

著者関連情報
© 社団法人日本機械学会