ねじりテープ挿入管の沸騰熱伝達における遷移特性
鈴木 伸寿熊谷 哲
著者情報
ジャーナル フリー

1996 年 62 巻 598 号 p. 2356-2362

詳細
抄録

An internal twisted tape, when used to initiate subcooled swirling flow boiling, is a very effective method of cooling components which are subject to high heat flux in a fusion reactor. In this study, the swirled channel was constructed using a copper cylinder (8mm inside diam., 190mm outside diam., and l00mm heating length), which was equipped with a twisted aluminum tape (approx. 0.5mm thick and 7.5mm wide), The values of the tape-twist ratio y (the length required to complete a single 180-degree twist of the tape divided by the inside tube diameter) were approximately l.8, 2.5, 3.2, 4.2, and infinity. CHF dependence on flow velocity and tape-twist was determined. Heating and cooling processes of large thermal capacity and inertia were used to obtain the wall heat flux via quasi-steady conditions, and several results for these limited cases are presented in the transition region near atmospheric pressure.

著者関連情報
© 社団法人日本機械学会