日本機械学会論文集 B編
Online ISSN : 1884-8346
Print ISSN : 0387-5016
高熱負荷狭隘流路におけるサブクール沸騰限界熱流束(熱工学, 内燃機関, 動力など)
呉田 昌俊秋本 肇
著者情報
ジャーナル フリー

2001 年 67 巻 662 号 p. 2550-2557

詳細
抄録

The purpose of this study is to propose the critical heat flux (CHF) correlation for narrow oneside heated rectangular channels. CHF of subcooled flow boiling of water in narrow rectangular channels under the atmospheric pressure was measured parametrically. Experimental test channels were rectangular channels heated from one side with channel gap of 0.2-3.0mm, channel of 7-22mm, and heated length of 50-100mm. CHF correlation for one-side heated rectangular channels was shown. Next, applicability of the correlation to the both-side heated rectangular channel, the half-circumferentially heated tube, and full-circumferentially heated tubes was examined. New CHF correlation for one-and both-side heated rectangular channels, and half-and full-circumferentially heated round tubes was proposed using critical quality, non-dimensional CHF parameter and heated perimeter ratio. Calculation error of the correlation is ±45% (Maximum 10 times better than the existing CHF evaluation equations which were proposed for the full-circumferentially heated tubes).

著者関連情報
© 社団法人日本機械学会
前の記事 次の記事
feedback
Top