日本機械学会論文集 B編
Online ISSN : 1884-8346
Print ISSN : 0387-5016
二相閉ループ型熱サイフォンによるCPUの冷却に関する実験的研究
儀間 悟長田 孝志張 興藤井 丕夫
著者情報
ジャーナル フリー

2004 年 70 巻 694 号 p. 1504-1509

詳細
抄録

This paper reports on indirect cooling of high-power CPU of notebook computers using a two phase closed thermosyphon loop with Fluorinert (FC-72) as the working fluid. The experimental set-up consists of an evaporator and a condenser connected by flexible tubing. The evaporator corresponds to a high-power CPU, and the condenser represents a cooling plate located behind the display of notebook computer, The evaporator and the condenser have the outer dimensions of 50mm×50mm×20mm and 150mm×200mm×20mm, respectively. The effects of the heat input Q and the charged volume of Fluorinert liquid F on the heat transfer characteristics of the cooling system were studied experimentally. Further, the experiments using several types of evaporators to enhance the boiling in the evaporator were carried out. It has been confirmed that the back surface temperature of the evaporator with plate fin of roughness surface by blast (Type D) reduces about 18% in comparison with that of the evaporator without fin (Type A). In the case of the evaporator Type D, the temperature difference between the evaporator back surface and ambient is kept around 55 K for the highest heat input Q=30 W in the present experiments.

著者関連情報
© 社団法人日本機械学会
前の記事 次の記事
feedback
Top