PEFCにおける内部漏洩電流が出力電圧に与える影響
開路及び閉路小電流域の内部漏洩電流
許斐 敏明川上 淳立花 秀晃
著者情報
ジャーナル フリー

2005 年 71 巻 712 号 p. 3025-3030

詳細
抄録

Over voltages and internal leak current density in PEFC were analyzed by FFT impedance method. Results showed that the conventional coefficient of Butler·Volmer's equation was twice as theoretical one. The coefficient measured by FFT impedance method was corresponding to the theoretical one. Measured internal leak current density in PEFC is 7.5 mA/cm2, and it reduces output voltage from 3 to 13 mV. Sum of the over voltages by the leak current and the known is 20-30%lower than Nernstian theoretical potential. Analysis and improvement of the unknown over voltages such as mixed potential and so on, will make big performance increase in PEFC.