突起壁面に衝突するディーゼル噴霧の混合気形成過程
林 義裕若林 千裕古畑 朋彦新井 雅隆
著者情報
ジャーナル フリー

2006 年 72 巻 716 号 p. 1021-1028

詳細
抄録

Mixture formation of diesel spray impinged on an extruded surface, which was a top of cylindrical column, was investigated experimentally. A diesel spray was impinged vertically to the extruded surface. The behaviors of impinged spray were observed using a high-speed drum camera. A spray volume was estimated from the photographs. Effect of cylindrical column diameter on spray behavior was investigated. Adhering fuel was measured by a primitive “wiping by paper and mass measuring” method under various conditions. Air-fuel ratio in spray was calculated from spray volume and adhering fuel. As the result, the behavior of diesel spray impinged on an extruded column was strongly influenced by the diameter of the extruded column. From the measured results, it is clear that the air-fuel ratio in spray in the extruded column diameter of 45 mm was larger than those in the other columns.

著者関連情報
© 社団法人日本機械学会
前の記事 次の記事