日本機械学会論文集 B編
Online ISSN : 1884-8346
Print ISSN : 0387-5016
Pyrromethene 546を用いた温度と圧力の分離同時画像計測
佐伯 壮一菅川 真一斉藤 俊河野 俊一
著者情報
ジャーナル フリー

2007 年 73 巻 726 号 p. 538-543

詳細
抄録

Recently, Temperature/Pressure Sensitive Paint (T/PSP) has been promising as a 2-dimentional quantitative optical measurement, because T/PSP is a very simple system with high spatial resolution. However, PSP depends generally on temperature as well as pressure. It is, therefore, necessary to eliminate temperature sensitivity in spite of having still pressure sensitivity. In this study, a mixed dye system ; Pyrromethene 546 and Ru (dpp) 3Cl2, is proposed as a temperature-independent PSP. Temperature variation of this system was experimentally found to be reduced to 95% in comparison with that of single PSP dye ; i.e. Ru (dpp) 3Cl2, because these dyes have opposite temperature dependencies in the same spectral band. Furthermore, the spectrum of the mixed dye system can be separated in respective spectral bands, which can be employed as temperature-independent and pressure-independent band. We constructed a dual emission imaging system ; i.e. 2-camera system, which was able to simultaneously capture images under both spectral bands. Consequently, it was verified that, using this system with proposed mixed P/TSP dye, temperature and pressure distribution can be independently measure at the same time.

著者関連情報
© 社団法人日本機械学会
前の記事 次の記事
feedback
Top