小型空冷ファンの風量に及ぼす障害物の影響(流体工学,流体機械)
中村 元福江 高志小泉 雄大石塚 勝
著者情報
ジャーナル フリー

2010 年 76 巻 768 号 p. 1184-1190

詳細
抄録

A compact air-cooling device often encounters high-density mounting environment, which may reduce a flow-rate of a cooling fan. In this work, the PQ characteristics of a cooling fan was investigated which varied by placing an obstacle in close proximity of a fan. Small axial-flow fans of 30-80mm in side length and small centrifugal fans of 35-52mm in side length were tested here. As a result, it was found that the maximum flow rate for the free air-flow begin to decrease when the opening area of the gap-flow between the fan and the obstacle becomes smaller than twice the fan flow area, and decreases suddenly if it becomes smaller than the fan flow area. This relation was almost independent of type and size of a fan, rotation speed of impeller, and shape and position of an obstacle.