日本機械学会論文集C編
Online ISSN : 1884-8354
ISSN-L : 1884-8354
一般論文
非接触型変位計を用いた小口径配管の振動応力評価法
前川 晃野田 満靖
著者情報
ジャーナル フリー

2011 年 77 巻 780 号 p. 3025-3035

詳細
抄録

In this study, a method using optical contactless displacement sensors to evaluate vibrational stress was proposed. As sensors, light-emitting diodes were used. The values measured with multiple displacement sensors were used in the proposed method to approximately calculate deformation shape, that is, curvature radius which occurs within a relatively narrow area of anything to be measured, and then the vibrational stress was obtained using the curvature radius. The vibrational stress was compared with the stress obtained by the conventional method using strain gauges, and the applicability of the proposed method was verified. Furthermore, the measurement accuracy was discussed from a sensitivity analysis with regard to the signal-to-noise ratio during the measurements.

著者関連情報
© 2011 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top