日本機械学会論文集 C編
Online ISSN : 1884-8354
Print ISSN : 0387-5024
三次元座標測定機の精度向上に関する基礎的研究 : 誤差補正法
大矢 誠穂刈 久田村 久司
著者情報
ジャーナル フリー

1986 年 52 巻 484 号 p. 3236-3242

詳細
抄録

To improve the accuracy of the three-coordinate measuring machine, a method of correcting the error in the coordinate measurement is proposed. The discrete distribution of the error vector can be determined, as was reported in the earlier papers. The correcting method is as follows : (1) The measuring range is divided into a number of elements of a rectangular prism, (2) The error vector is presumed with the interpolation polinominal for the element in which the probe is positioned, (3) The results of the coordinate measurement are corrected by the presumed error vector. In order to confirm the method, measurements are made on both distance and flatness, and the results are corrected using the proposed method. It is shown that the corrected values are closer to the true values, and that the method proposed here is useful for improving the accuracy of the three-coordinate measuring machine.

著者関連情報
© 社団法人日本機械学会