日本機械学会論文集 C編
Online ISSN : 1884-8354
Print ISSN : 0387-5024
電気・構造・音場連成系の着目する周波数帯域の解析
河村 庄造枩田 健志岩壷 卓三塩幡 宏規
著者情報
ジャーナル フリー

1998 年 64 巻 618 号 p. 386-393

詳細
抄録

When an acoustic field in an enclosed space is controlled using the structural vibration control by the piezoelectric actuator, electric system, structural system and acoustic system are influenced each other. Thus this system must be considered as electric-structural-acoustic coupled system. In this paper, the analysis in the required frequency band of electric-structural acoustic coupled system has been carried out. In this analysis, the structural vibration is approximated by the superposition of the electric-structural coupled vibration modes which are included in the required frequency band, and the truncated frequency band are compensated by the residual terms. This truncation method is the application of the authers' previous method. As a numerical example, a flexible rectangular prism model is taken up and the vibration of structure, the voltage of piezoelectric actuator and the sound pressure in the model are calculated using the proposed method. It is shown that the analysis of coupled system has reached the accurate results comparing with the one of nucoupled system, the calculated results using the proposed method agree with the exact ones which are obtained by using the full frequency band, and calculation time is saved.

著者関連情報
© 社団法人日本機械学会
前の記事 次の記事
feedback
Top