Mechanical Engineering Journal
Online ISSN : 2187-9745
ISSN-L : 2187-9745
Thermal, Engine and Power Engineering
Estimation of long-term ex-vessel debris cooling behavior in Fukushima Daiichi Nuclear Power Plant unit 3
Ikken SATOAkifumi YAMAJIXin LIHiroshi MADOKORO
Author information
JOURNAL OPEN ACCESS

2022 Volume 9 Issue 2 Pages 21-00436

Details
Abstract

Interpretation for the two-week long Unit 3 ex-vessel debris cooling behavior was conducted based on the Fukushima-Daiichi Nuclear Power Plant (1F) data and the site data such as pressure, temperature, gamma ray level and live camera pictures. It was estimated that the debris relocated to the pedestal was in partial contact with liquid water for about initial two days. With the reduction of the sea water injection flowrate, the debris, existed mainly in the pedestal region, became “dry”, in which the debris was only weakly cooled by vapor and this condition lasted for about four days until the increase of the sea water injection. During this dry period, the pedestal debris was heated up and it took further days to re-flood the heated up debris.

Content from these authors
© 2022 The Japan Society of Mechanical Engineers

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/
Previous article Next article
feedback
Top