特集:人工膜シンポジウム1「膜による水処理技術を展望するXV~高度膜濃縮技術」
正浸透膜・膜蒸留を用いた非加熱濃縮膜システムの開発
~医薬製造分野への応用~
佐藤 俊太片山 雄治美河 正人
著者情報
ジャーナル 認証あり

2024 年 49 巻 5 号 p. 243-248

詳細
抄録
Non–heated concentration membrane system has been developed by using FO (Forward Osmosis) and MD (Membrane Distillation) membrane. FO mainly removes water with osmotic pressure difference between Feed Solution (FS) and Draw Solution (DS). On the other hand, MD mainly removes solvent such as acetonitrile with vapor pressure difference between FS and Cooling Water (CW). This system is applied to pharmaceutical manufacturing processes that are sensitive to heat and pressure such as peptides and oligonucleotides. This is the only one technology which can concentrate the liquids without heat and pressure, and control liquid composition at the same time. This review includes the test results with the cyclic peptide solution, which demonstrates the potential of the FO–MD system in pharmaceutical manufacturing processes.