Abstract
A three-cup anemometer and a combination wind vane and anemometer model are tested in wind tunnel as to their rotational speed in the presence of a cylindrical obstacle. Somewhat consistent and remarkable errors in reading, especially in the lee-side, are observed which should be taken into account in wind speed measurement at towers, pylons etc.