Magnetic Resonance in Medical Sciences
Online ISSN : 1880-2206
Print ISSN : 1347-3182
ISSN-L : 1347-3182
Major Papers
Origin of Dissolved-phase Hyperpolarized 129Xe Signal in the Mouse Chest Based on Experimental Evidence from Extensive Magnetic Resonance Measurements
Michiko NARAZAKIAtsuomi KIMURATetsuya WAKAYAMAHirohiko IMAIHideaki FUJIWARA
著者情報
ジャーナル オープンアクセス

2011 年 10 巻 3 号 p. 149-154

詳細
抄録
Pulmonary study using hyperpolarized (HP) 129Xe gas as an imaging medium must focus on dissolved-phase signals to make the most of the characteristic affinity of xenon for biological tissues, including blood. However, the spectral pattern of these signals differs between mice and other animals, including rats, canines, and humans. Dissolved-phase study has been reported only scarcely in mice, so spectral assignment has been an important subject for HP 129Xe magnetic resonance (MR) spectroscopy (MRS) and MR imaging for its wider application. We performed MRS, including magnetization transfer experiments, and MR imaging studies to confirm the origin of dissolved-phase signals of mice ex vivo and in vivo and obtained evidence to assign dissolved-phase signals at 192 ppm for epicardial fat, 196 ppm for lung parenchyma, and 200 ppm for blood. These results were the first to show the possibility of fast exchange of xenon between plasma and red blood cells.
著者関連情報
© 2011 by Japanese Society for Magnetic Resonance in Medicine
前の記事 次の記事