Magnetic Resonance in Medical Sciences
Online ISSN : 1880-2206
Print ISSN : 1347-3182
ISSN-L : 1347-3182
Technical Note
Imaging of Ménière's Disease by Subtraction of MR Cisternography from Positive Perilymph Image
Shinji NAGANAWAMasahiro YAMAZAKIHisashi KAWAIKiminori BOKURAMichihiko SONETsutomu NAKASHIMA
著者情報
ジャーナル オープンアクセス

2012 年 11 巻 4 号 p. 303-309

詳細
抄録
To visualize endolymph, perilymph, and bone separately in a single image after intravenous injection of single-dose gadodiamide, we generated a HYDROPS2 image (subtraction of MR cisternography from heavily T2-weighted 3-dimensional fluid-attenuated inversion recovery image) in 12 patients with suspected Ménière's disease. The contrast-to-noise ratio of endo- and perilymph did not differ significantly between the HYDROPS2 and previously reported HYDROPS (hybrid of reversed image of positive endolymph signal and native image of positive perilymph Signal) images, and scan time was 40% shorter for the HYDROPS2 than HYDROPS.
著者関連情報
© 2012 by Japanese Society for Magnetic Resonance in Medicine
前の記事
feedback
Top