Magnetic Resonance in Medical Sciences
Online ISSN : 1880-2206
Print ISSN : 1347-3182
ISSN-L : 1347-3182
Major Papers
Differentiating between Central Nervous System Lymphoma and High-grade Glioma Using Dynamic Susceptibility Contrast and Dynamic Contrast-enhanced MR Imaging with Histogram Analysis
Kazuhiro MurayamaYuya NishiyamaYuichi HiroseMasato AbeShigeharu OhyuAyako NinomiyaTakashi FukubaKazuhiro KatadaHiroshi Toyama
著者情報
ジャーナル オープンアクセス

2018 年 17 巻 1 号 p. 42-49

詳細
抄録

Purpose: We evaluated the diagnostic performance of histogram analysis of data from a combination of dynamic susceptibility contrast (DSC)-MRI and dynamic contrast-enhanced (DCE)-MRI for quantitative differentiation between central nervous system lymphoma (CNSL) and high-grade glioma (HGG), with the aim of identifying useful perfusion parameters as objective radiological markers for differentiating between them.

Methods: Eight lesions with CNSLs and 15 with HGGs who underwent MRI examination, including DCE and DSC-MRI, were enrolled in our retrospective study. DSC-MRI provides a corrected cerebral blood volume (cCBV), and DCE-MRI provides a volume transfer coefficient (Ktrans) for transfer from plasma to the extravascular extracellular space. Ktrans and cCBV were measured from a round region-of-interest in the slice of maximum size on the contrast-enhanced lesion. The differences in t values between CNSL and HGG for determining the most appropriate percentile of Ktrans and cCBV were investigated. The differences in Ktrans, cCBV, and Ktrans/cCBV between CNSL and HGG were investigated using histogram analysis. Receiver operating characteristic (ROC) analysis of Ktrans, cCBV, and Ktrans/cCBV ratio was performed.

Results: The 30th percentile (C30) in Ktrans and 80th percentile (C80) in cCBV were the most appropriate percentiles for distinguishing between CNSL and HGG from the differences in t values. CNSL showed significantly lower C80 cCBV, significantly higher C30 Ktrans, and significantly higher C30 Ktrans/C80 cCBV than those of HGG. In ROC analysis, C30 Ktrans/C80 cCBV had the best discriminative value for differentiating between CNSL and HGG as compared to C30 Ktrans or C80 cCBV.

Conclusion: The combination of Ktrans by DCE-MRI and cCBV by DSC-MRI was found to reveal the characteristics of vascularity and permeability of a lesion more precisely than either Ktrans or cCBV alone. Histogram analysis of these vascular microenvironments enabled quantitative differentiation between CNSL and HGG.

著者関連情報
© 2018 by Japanese Society for Magnetic Resonance in Medicine

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/
前の記事 次の記事
feedback
Top