Magnetic Resonance in Medical Sciences
Online ISSN : 1880-2206
Print ISSN : 1347-3182
ISSN-L : 1347-3182

This article has now been updated. Please use the final version.

Effect of Temporal Sampling Rate on Estimates of the Perfusion Parameters for Patients with Moyamoya Disease Assessed with Simultaneous Multislice Dynamic Susceptibility Contrast-enhanced MR Imaging
Tomohiro TakamuraShoko HaraTadashi NariaiYutaka IkenouchiMichimasa SuzukiToshiaki TaokaMasahiro IdaKeiichi IshigameMasaaki HoriKanako SatoKoji KamagataKanako KumamaruHidenori OishiSho OkamotoYoshio ArakiKenji UdaMasakazu MiyajimaTaketoshi MaeharaMotoki InajiYoji TanakaShinji NaganawaHisashi KawaiToshiki NakaneYasuaki TsurushimaToshiyuki OnoderaShuko NojiriShigeki Aoki
Author information
JOURNAL OPEN ACCESS Advance online publication
Supplementary material

Article ID: mp.2021-0162

Details
Abstract

Purpose: The effect of temporal sampling rate (TSR) on perfusion parameters has not been fully investigated in Moyamoya disease (MMD); therefore, this study evaluated the influence of different TSRs on perfusion parameters quantitatively and qualitatively by applying simultaneous multi-slice (SMS) dynamic susceptibility contrast-enhanced MR imaging (DSC-MRI).

Methods: DSC-MRI datasets were acquired from 28 patients with MMD with a TSR of 0.5 s. Cerebral blood flow (CBF), cerebral blood volume (CBV), mean transit time (MTT), time to peak (TTP), and time to maximum tissue residue function (Tmax) were calculated for eight TSRs ranging from 0.5 to 4.0 s in 0.5-s increments that were subsampled from a TSR of 0.5 s datasets. Perfusion measurements and volume for chronic ischemic (Tmax ≥ 2 s) and non-ischemic (Tmax < 2 s) areas for each TSR were compared to measurements with a TSR of 0.5 s, as was visual perfusion map analysis.

Results: CBF, CBV, and Tmax values tended to be underestimated, whereas MTT and TTP values were less influenced, with a longer TSR. Although Tmax values were overestimated in the TSR of 1.0 s in non-ischemic areas, differences in perfusion measurements between the TSRs of 0.5 and 1.0 s were generally minimal. The volumes of the chronic ischemic areas with a TSR ≥ 3.0 s were significantly underestimated. In CBF and CBV maps, no significant deterioration was noted in image quality up to 3.0 and 2.5 s, respectively. The image quality of MTT, TTP, and Tmax maps for the TSR of 1.0 s was similar to that for the TSR of 0.5 s but was significantly deteriorated for the TSRs of ≥ 1.5 s.

Conclusion: In the assessment of MMD by SMS DSC-MRI, application of TSRs of ≥ 1.5 s may lead to deterioration of the perfusion measurements; however, that was less influenced in TSRs of ≤ 1.0 s.

Content from these authors
© 2022 by Japanese Society for Magnetic Resonance in Medicine

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/
feedback
Top