2001 年 50 巻 3 号 p. 848-851
Six patients with spinal tumor were operated on using titanium mesh cages. Four patients were male and two were female. The average age of the patients was 54 years (range: 40 to 65 years). Three cases were of the cervical level and the others were thoracic. All patients had severe neck or back pain, and one patient had nerve pain. The follow-up ranged from 4 to 17 months (mean: 9.2 months). Four patients received the anteroposterior approach, and two the anterior approach.
The operative time was 150 to 255 minutes (mean: 195 minutes). The mean intraoperative blood loss came to 330g (range: 70 to 750g). All patients reported that their pain decreased or disappeared. No cage failure or extrusion was observed.