Neurologia medico-chirurgica
Online ISSN : 1349-8029
Print ISSN : 0470-8105
ISSN-L : 0470-8105
Technical Note
Continuous Suction Method in Superficial Temporal Artery-Middle Cerebral Artery Anastomosis Surgery
—Technical Note—
Jun-ichi KOYAMAYuichiro TANAKATomomi IWASHITAKazuo KITAZAWAKazuhiro HONGO
Author information
JOURNAL OPEN ACCESS

2006 Volume 46 Issue 5 Pages 262-264

Details
Abstract

A new method was developed to maintain a bloodless microscopic operative field for superficial temporal artery-middle cerebral artery (MCA) anastomosis surgery. A silicone suction tube with multiple holes is placed circumferentially under the reflected dural flaps around the craniotomy. Blood and irrigated saline are continuously aspirated by the tube. Use of this method in nine patients significantly reduced the mean MCA trapping time (24.0 ± 2.8 min) compared with nine patients treated using the conventional method (30.1 ± 4.6 min). MCA trapping time is shortened because the surgery is not interrupted for manual suctioning of bloody cerebrospinal fluid.

Content from these authors
© 2006 by The Japan Neurosurgical Society

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/
Previous article Next article
feedback
Top