Neurologia medico-chirurgica
Online ISSN : 1349-8029
Print ISSN : 0470-8105
ISSN-L : 0470-8105
Technical Note
Higher Magnification Microsurgical Repair of Donor Artery Dissection in Superficial Temporal Artery to Middle Cerebral Artery Anastomosis
—Technical Note—
Nobuhisa MATSUMURATakashi SHIBATAHironaga KAMIYAMATakahiro TOMITASoushi OKAMOTOMichiya KUBOYukio HORIE
Author information
JOURNAL OPEN ACCESS

2011 Volume 51 Issue 12 Pages 872-874

Details
Abstract
Donor artery dissection is a known cause of technical failure in microvascular anastomosis. A method for detection and direct repair of donor artery dissection before superficial temporal artery (STA) to middle cerebral artery (MCA) anastomosis is described using a high magnification operating microscope (maximum 50.4× magnification). Before STA-MCA anastomosis, the stump of the STA is stained using methylrosaniline chloride (pyoctaninum blue) and is observed under higher magnifications. Microsurgical suturing of the arterial dissection is performed before the anastomosis procedure under the high magnification microscope. This method was used in two patients with symptomatic hemodynamic cerebrovascular occlusive disease. Postoperative angiography revealed good patency and no complications occurred. This method may be useful for detection and direct repair of arterial dissection in small vessel walls before STA-MCA anastomosis.
Content from these authors
© 2011 by The Japan Neurosurgical Society

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/
Previous article Next article
feedback
Top