Optical Review
Print ISSN : 1340-6000
ISSN-L : 1340-6000
Measurement of Dihedral Angle Errors of a Large-Aperture Space Retroreflector: Separation of the Effect of Sag Due to Gravity
Atsushi MINATONobuo SUGIMOTOZvi BLEIERGeorge C. HUNTERJames PAUL
Author information
JOURNAL FREE ACCESS

1995 Volume 2 Issue 4 Pages 319-322

Details
Abstract
A 50-cm diameter hollow cube-corner retroreflector for a space application was tested with a 60-cm interferometer. To separate the effect of sag due to gravity, the interferograms were taken at six rotational positions, with the retroreflector mounted horizontally. The zero-gravity dihedral angles and the effect of sag were estimated from the interferograms.
Content from these authors

This article cannot obtain the latest cited-by information.

© 1995 by the Optical Society of Japan
Previous article Next article
feedback
Top