A Multipoint Quasi-Distributed Optical Fiber pH Sensor
Michael CAMPBELLYatao YANGPeter A. WALLACEA. Sheila HOLMES–SMITH
著者情報
ジャーナル フリー

1997 年 4 巻 1A 号 p. 111-113

詳細
抄録
This paper reports the development and characterisation of a multipoint quasi-distributed optical fiber sensor for pH measurement. The system is based on a 170 m length of 200 μm core diameter plastic cladding silica fiber where sections of cladding have been removed and replaced with dye immobilised sol-gel glass to form sensing points. Evanescent wave excitation of a dye, immobilised within 2 mm long sections of cladding, enables the pH value of any spillage material to be determined by optical time domain reflectometry along the length of the fiber. The results suggest a spatial resolution of better than 2.5 meters for this fiber system and indicate that this arrangement could form the basis of a practical sensor/actuator system for chemical spillage, provided that suitable dye/analyte combinations are available.